Verified Electrical & Mechanical Specifications
Product Overview & Dielectric Architecture
MKP-LS is a self-healing high-voltage DC-link capacitor built for compact, high-reliability bus filtering in PV and ESS inverters, industrial welding machines, UPS conversion stages, EV auxiliary DC-DC rails, and high-current servo drives. The dielectric is metallized polypropylene film in a dry, self-healing element, so a local breakdown clears itself instead of shorting the bus. Standard ratings span 500V to 1400V DC, with 1100V and 1200V DC as the common working points, and typical capacitance from 100µF to 420µF at ±5% (J) or ±10% (K).
The series is rated for -40°C to +85°C, with 1.33%/°C derating permitted up to 105°C, and carries a 50,000-hour life expectancy at rated voltage and 85°C. A representative build is 420µF at 1200V DC. For OEM buyers, MKP-LS fills the gap between small PCB DC-link parts and large aluminum-can banks: it delivers high-voltage bus support in a compact, fast-delivery package suited to mid-power inverter platforms.
Electrical Behavior & Compliance Standards
Electrically, MKP-LS behaves as a low-loss DC bus reservoir. The metallized polypropylene element gives stable capacitance and low dissipation across switching frequencies, which keeps ripple heating modest under continuous PWM current. Self-healing is the core safety mechanism: a fault site vaporizes its thin metal layer and isolates the defect, so the capacitor degrades gracefully rather than failing short. The dry element construction avoids liquid leakage risk and supports the 50,000-hour life target at rated voltage and 85°C.
Thermal design matters as much as ESR. Above 85°C, apply the 1.33%/°C voltage derating to hold margin at the hot spot. The series is tested to 1.5× rated voltage for 10 seconds terminal-to-terminal and 3000V AC at 50Hz for 10 seconds terminal-to-case, with insulation resistance above 10,000 s (IR × Cn, 20°C, 100V DC, 1 minute). Reference standards are GB/T 17702 and IEC 61071, the framework OEM engineers should cite in DC-link qualification and type-test documents.
Circuit Selection & Typical Applications
Sizing MKP-LS starts with the bus voltage and ripple current, not capacitance alone. Pick a rated voltage at least 1.2× the maximum DC bus, then confirm the RMS ripple current at your switching frequency and hot-spot temperature. Use the 1.33%/°C derating above 85°C, and check that the 50,000-hour life target matches the inverter service life. Capacitance is then set by allowable bus voltage ripple and hold-up time.
- Define Vbus maximum, switching frequency, and expected RMS ripple current before choosing 100µF to 420µF.
- Select 1100V or 1200V DC standard ratings for common 800V–1000V bus platforms; use 500V–1400V DC options for other rails.
- Choose ±5% (J) where loop stability or parallel balancing is tight; ±10% (K) is usually sufficient for bulk bus support.
- Verify terminal-to-case clearance and 3000V AC isolation for your enclosure and creepage requirements.
- Confirm mounting, terminal style, and marking with SMILER early, since OEM customization is available.
- PV & ESS Inverters
- Industrial Inverter Welding Machines
- UPS Power Conversion
- EV Auxiliary DC-DC Stages
- High-Current Servo Drives
OEM Manufacturing & Quality Screening
SMILER produces MKP-LS in Foshan, Guangdong, in a 5,000 m² plant with 9 production lines and about 300,000 units daily output. Every unit passes 100% electrical screening, including DC withstand voltage testing and leak inspection, backed by a 7-member QA/QC team and an in-house laboratory. Finished-product qualification rate is maintained at ≥99.93%, which matters for OEM lines running continuous inverter assembly.
Prototyping is fast: the shortest sample lead time is 5 days, and average mass production delivery is 15 days. OEM customization covers capacitance, voltage rating, case dimensions, terminal and pin configuration, and private-label marking. Share your bus voltage, ripple profile, and mechanical envelope, and the engineering team can match MKP-LS to your platform.
Explore related industrial solutions, browse our engineering selection guides, or request a MKP-LS datasheet and sample quote.
MKP-LS Frequently Asked Questions
What is the maximum DC voltage rating available for MKP-LS?
MKP-LS is rated from 500V to 1400V DC, with 1100V and 1200V DC as standard working points. Operation is specified from -40°C to +85°C, with 1.33%/°C derating allowed up to 105°C. Choose a rating at least 1.2× your maximum bus voltage for margin.
How do I estimate MKP-LS life in a PV inverter at 85°C?
The published life expectancy is 50,000 hours at rated voltage and 85°C. Above 85°C, apply the 1.33%/°C voltage derating to preserve margin. Actual life also depends on ripple current and hot-spot temperature, so confirm your RMS ripple profile against the datasheet before final selection.
Does SMILER offer custom capacitance and terminals for MKP-LS?
Yes. SMILER supports OEM customization of capacitance, voltage rating, case dimensions, terminal and pin configuration, and private-label marking. Samples can be ready in as little as 5 days, with average mass production delivery around 15 days from the Foshan plant.
Related Capacitor Series
Need Datasheets or Custom OEM Film Capacitors?
Send your capacitance, voltage rating, and mechanical drawing. Our 9-member engineering team replies within 24 hours with 5-day prototyping availability.