CD60 High-Torque AC Motor Start Capacitor — Direct OEM Factory

Heavy-duty intermittent-duty AC motor starting capacitor rated 110V–450V AC (50–400µF standard; 1–120µF custom) per IEC 60252-2 for compressors and pumps.

SMILER CD60 cylindrical AC motor starting capacitor for compressors and pumps

Verified Electrical & Mechanical Specifications

Rated Voltage
110V – 450V AC (50/60Hz)
Capacitance Range
50µF – 400µF standard (1µF – 120µF custom builds)
Tolerance
±5% (J), ±10% (K)
Operating Temperature
-20°C to +65°C
Dissipation Factor
tg δ ≤ 0.15 (100Hz, 20°C)
Dielectric Test
1.2×Un / 2s (t-t); 2000V AC (t-c)
Housing
Flame-Retardant Plastic or Aluminum Shell
Reference Standards
IEC 60252-2, GB/T 3667.2
Request a Quote for CD60 Back to All Series

Product Overview & Dielectric Architecture

CD60 is a high-torque AC motor start capacitor engineered to deliver a short, powerful burst of capacitance during the start winding phase of single-phase induction motors. Its metallized polypropylene dielectric is wound into a compact core and housed in flame-retardant plastic or an aluminum shell, giving OEMs a choice between cost-sensitive and ruggedized builds. Standard ratings span 110V to 450V AC at 50/60Hz, with capacitance from 50µF to 400µF and custom builds down to 1µF–120µF.

These capacitors are typically applied to air conditioner and freezer compressors, high-torque water pumps, air compressors, and agricultural motors where locked-rotor torque demands exceed what a run capacitor alone can supply. Tolerance options of ±5% (J) and ±10% (K) let design teams balance starting torque consistency against cost. The -20°C to +65°C operating window suits most compressor decks and pump housings, while the dissipation factor of tg δ ≤ 0.15 at 100Hz, 20°C keeps losses predictable during brief start cycles.

Electrical Behavior & Compliance Standards

Electrically, CD60 behaves as a high-capacitance reservoir that is switched into the auxiliary winding only during acceleration, then disconnected by a centrifugal switch or start relay. Because the start interval is short, the capacitor is optimized for high initial current delivery rather than continuous ripple handling. The metallized polypropylene construction provides self-healing behavior: a dielectric breakdown clears locally and the capacitor continues to function, which is a key safety margin in compressor start circuits. The flame-retardant housing and aluminum shell option add mechanical and thermal robustness for OEM assembly lines.

Thermal design centers on the +65°C upper limit and the dissipation factor ceiling of tg δ ≤ 0.15, which governs internal heating during repeated start attempts. The series is referenced to IEC 60252-2 and GB/T 3667.2, the standards covering AC motor start capacitors. Dielectric verification includes 1.2×Un for 2 seconds terminal-to-terminal and 2000V AC terminal-to-case, giving OEMs a documented basis for incoming inspection and end-product safety testing.

Circuit Selection & Typical Applications

Sizing CD60 starts with the motor's locked-rotor current and the start winding's required phase shift. Engineers typically calculate the capacitance needed to maximize starting torque at the lowest expected line voltage, then confirm the selected value stays within the compressor or pump manufacturer's start-winding current limit. The table below summarizes the practical selection path.

  • Match rated voltage to the highest line voltage plus margin; 110V–450V AC covers common single-phase supplies.
  • Choose capacitance from 50µF–400µF for standard compressor and pump duties, or specify a 1µF–120µF custom build for smaller motors.
  • Select ±5% (J) tolerance where torque consistency matters, ±10% (K) where cost dominates.
  • Confirm the -20°C to +65°C range against the enclosure's ambient profile and duty cycle.
  • Pick flame-retardant plastic for light-duty appliances or aluminum shell for harsh pump and agricultural environments.
  • Verify terminal and mounting geometry against the start relay or switch assembly before tooling release.
  • Air Conditioner & Freezer Compressors
  • High-Torque Water Pumps
  • Air Compressors & Agricultural Motors
  • Single-Phase Induction Motor Starting

OEM Manufacturing & Quality Screening

SMILER manufactures CD60 and related motor capacitors at its Foshan Shunde facility, a 5,000 m² plant with nine production lines and roughly 300,000 units daily output. Every unit passes 100% electrical screening, including DC withstand voltage testing and leak inspection, supported by a seven-person QA/QC team and an in-house laboratory. Finished-product qualification rate is maintained at ≥99.93%, giving OEM buyers a stable baseline for incoming quality audits.

Prototyping runs as fast as five days, and average mass production delivery is 15 days. OEM customization covers capacitance, rated voltage, housing dimensions, terminal and pin configurations, and private-label marking. For compressor, pump, and agricultural motor programs, this lets procurement teams lock a start capacitor specification early in the design cycle and scale to volume without re-qualifying a second source.

Explore related industrial solutions, browse our engineering selection guides, or request a CD60 datasheet and sample quote.

CD60 Frequently Asked Questions

What voltage and capacitance range does CD60 cover?

CD60 is rated from 110V to 450V AC at 50/60Hz. Standard capacitance runs from 50µF to 400µF, with custom builds available from 1µF to 120µF. Tolerance is ±5% (J) or ±10% (K), and the operating temperature range is -20°C to +65°C.

Which standards and dielectric tests apply to CD60?

The series references IEC 60252-2 and GB/T 3667.2. Dielectric testing includes 1.2×Un for 2 seconds terminal-to-terminal and 2000V AC terminal-to-case. Dissipation factor is tg δ ≤ 0.15 at 100Hz, 20°C, and housings are available in flame-retardant plastic or aluminum shell.

How fast can SMILER deliver CD60 samples and production orders?

Sample lead time can be as short as 5 days, and average mass production delivery is 15 days. The Foshan plant runs nine production lines with about 300,000 units daily output, and every unit undergoes 100% electrical screening before shipment.

Need Datasheets or Custom OEM Film Capacitors?

Send your capacitance, voltage rating, and mechanical drawing. Our 9-member engineering team replies within 24 hours with 5-day prototyping availability.

Request a Quote