CBB61 Fan & Blower Motor Run Capacitor — Direct Manufacturer

Rectangular flame-retardant motor run capacitor rated 110V–600V AC (standard 450V AC), 0.4µF–50µF with verified CB (CN65200), TUV, VDE, and RoHS compliance.

SMILER CBB61 rectangular fan motor run film capacitor 450V AC

Verified Electrical & Mechanical Specifications

Rated Voltage
110V – 600V AC 50/60Hz (standard 450V AC)
Capacitance Range
0.4µF – 50µF (common 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6, 10µF)
Tolerance
±5% (J), ±10% (K)
Climatic Category
40/70/21, 40/85/21, 40/105/21
Life & Safety Class
Class A (30,000h) / B (10,000h) / C (3,000h); S0–S3
Dissipation Factor
tg δ ≤ 0.0020 (100Hz)
Verified Certifications
CB (CN65200), TUV (R 50352497 0002), VDE (40034278), LVD, RoHS
Terminals & Case
Rectangular UL94 V-0 Case, Wire Leads, PCB Pins, or Mounting Lug
Request a Quote for CBB61 Back to All Series

Product Overview & Dielectric Architecture

CBB61 is a metallized polypropylene film capacitor built for continuous AC motor run duty in fans, blowers, and small single-phase HVAC motors. The dielectric is self-healing metallized polypropylene wound into a compact core, housed in a rectangular UL94 V-0 flame-retardant case with wire leads, PCB pins, or a mounting lug. Standard ratings span 110V–600V AC at 50/60Hz (450V AC is the common HVAC choice), with capacitance from 0.4µF to 50µF in ±5% (J) or ±10% (K) tolerance.

Typical catalog values include 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6, and 10µF. Dissipation factor stays at or below 0.0020 at 100Hz, keeping self-heating low during long run cycles. Climatic categories 40/70/21, 40/85/21, and 40/105/21 cover most ceiling fan, exhaust fan, air purifier, and air conditioner indoor blower designs. Life and safety classes A (30,000h), B (10,000h), and C (3,000h) with S0–S3 safety levels let OEM buyers match expected service life to the appliance warranty.

Electrical Behavior & Compliance Standards

In a permanent-split or capacitor-start-run motor, CBB61 shifts winding current to create starting torque and then holds a stable phase angle while the motor runs. Low dissipation factor (tg δ ≤ 0.0020 at 100Hz) limits dielectric heating, and the metallized film self-heals after localized breakdowns, clearing faults instead of failing short. The UL94 V-0 rectangular case and sealed winding resist moisture and dust in fan and blower housings. Safety class S0–S3 defines the failure-mode behavior expected in the end product.

Voltage rating must cover the motor's back-EMF and mains transients, so a 450V AC part is common on 220–240V systems. Thermal design follows the chosen climatic category: 40/70/21 for moderate fan duty, 40/85/21 or 40/105/21 for hot blower compartments. Verified approvals for this series include CB (CN65200), TUV (R 50352497 0002), VDE (40034278), LVD, and RoHS. Applicable standards for AC motor capacitors include IEC 60252-1 and the corresponding GB/T 3667.1 framework, which guide endurance, voltage proof, and safety testing.

Circuit Selection & Typical Applications

Sizing CBB61 starts with the motor, not the capacitor catalog. Confirm the required run capacitance from the motor nameplate or OEM drawing, then pick the nearest standard value within ±5% (J) where phase angle matters or ±10% (K) for cost-sensitive fan builds. Check the AC voltage against the highest RMS voltage the winding sees, including start transients, and choose a life class that matches the appliance warranty.

  • Match capacitance to the motor's run winding requirement; undersizing reduces torque, oversizing raises current and heating.
  • Select voltage rating with margin above nominal mains and back-EMF; 450V AC is standard for 220–240V fan and blower motors.
  • Choose climatic category by enclosure temperature: 40/70/21 for open fans, 40/85/21 or 40/105/21 for HVAC blowers and purifiers.
  • Pick terminal style early: wire leads for harness assembly, PCB pins for control boards, mounting lug for chassis fixing.
  • Confirm case dimensions and lead length against the fan housing drawing before tooling release.
  • Specify life class A, B, or C and safety class S0–S3 to align with appliance safety and warranty targets.
  • Ceiling Fans & Standing Fans
  • Exhaust Fans & Air Purifiers
  • Air Conditioner Indoor Blowers
  • Small Single-Phase HVAC Motors

OEM Manufacturing & Quality Screening

SMILER produces CBB61 in its Foshan, Guangdong facility, where 9 automated lines and 31 specialized machines handle slitting, winding, core pressing, spray metallization, assembly, and encapsulation. Every unit passes 100% electrical screening, including AC/DC empowerment and DC withstand voltage testing, supported by a 7-member QA/QC team and an in-house laboratory. Finished product qualification rate is maintained at ≥99.93%, and daily output reaches approximately 300,000 units.

OEM buyers get fast turnaround: prototype samples in as little as 5 days and average mass production delivery of 15 days. Customization covers capacitance, rated voltage, case dimensions, lead and terminal configuration, and private-label marking. The CBB61 series carries CB (CN65200), TUV (R 50352497 0002), VDE (40034278), LVD, and RoHS approvals, giving appliance makers documented compliance for fan, blower, and HVAC motor programs.

Explore related industrial solutions, browse our engineering selection guides, or request a CBB61 datasheet and sample quote.

CBB61 Frequently Asked Questions

What is the difference between life class A, B, and C for CBB61?

Life class defines expected endurance under rated conditions: Class A is 30,000 hours, Class B is 10,000 hours, and Class C is 3,000 hours. Choose Class A for long-life appliances such as ceiling fans, Class B for standard blowers, and Class C for short-duty or cost-driven fan designs.

Can CBB61 replace a failed run capacitor with a different capacitance value?

Use the motor manufacturer's specified capacitance. A small deviation within ±5% or ±10% tolerance is acceptable, but a significantly different value changes phase angle, torque, and winding current. Confirm the replacement voltage rating meets or exceeds the original, typically 450V AC for 220–240V fan motors.

Which terminal and mounting options are available for CBB61?

CBB61 is offered with wire leads, PCB pins, or a mounting lug, all in a rectangular UL94 V-0 case. Wire leads suit harness assembly in fan housings, PCB pins fit control boards, and mounting lugs secure the capacitor to chassis. Custom lead lengths and terminal layouts are available for OEM programs.

Need Datasheets or Custom OEM Film Capacitors?

Send your capacitance, voltage rating, and mechanical drawing. Our 9-member engineering team replies within 24 hours with 5-day prototyping availability.

Request a Quote